Cited 0 times in
High-sensitive LC-MS/MS method for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma: application to microdose clinical trials of mirodenafil.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, DY | - |
dc.contributor.author | Bae, SH | - |
dc.contributor.author | Shon, JH | - |
dc.contributor.author | Bae, SK | - |
dc.date.accessioned | 2014-06-02T03:31:55Z | - |
dc.date.available | 2014-06-02T03:31:55Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1615-9306 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/10330 | - |
dc.description.abstract | A high-sensitivity LC/MS/MS method was developed and validated for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma. Mirodenafil, SK-3541, and udenafil as an internal standard were extracted from plasma samples with methyl tert-butyl ether. Chromatographic separation was performed on a Luna phenyl-hexyl column (100 × 2.0 mm) with an isocratic mobile phase consisting of 5 mM ammonium formate and ACN (23:77, v/v) at a flow rate of 0.35 mL/min. Detection and quantification were performed using a mass spectrometer in selected reaction monitoring mode with positive ESI at m/z 532.3 → 296.1 for mirodenafil, m/z 488.1 → 296.1 for SK-3541, and m/z 517.3 → 283.2 for udenafil. The calibration curves were linear over a concentration range of 2-500 pg/mL using 0.5 mL plasma for the microdose of mirodenafil (100 μg). Analytical method validation of the clinical dose (100 mg), with a calibration curve range of 2-500 ng/mL using 0.025-mL plasma, was also conducted. The other LC-MS/MS conditions were similar to those used for the microdosing. Each method was applied successfully to pharmacokinetic studies after a microdose or clinical dose of mirodenafil to six healthy Korean male volunteers. | - |
dc.format | application/pdf | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Chromatography, High Pressure Liquid | - |
dc.subject.MESH | Drug Dosage Calculations | - |
dc.subject.MESH | Erectile Dysfunction | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Pyrimidines | - |
dc.subject.MESH | Pyrimidinones | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Sulfonamides | - |
dc.subject.MESH | Tandem Mass Spectrometry | - |
dc.subject.MESH | Young Adult | - |
dc.title | High-sensitive LC-MS/MS method for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma: application to microdose clinical trials of mirodenafil. | - |
dc.type | Article | - |
dc.identifier.pmid | 23390072 | - |
dc.contributor.affiliatedAuthor | 조, 두연 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1002/jssc.201200919 | - |
dc.citation.title | Journal of separation science | - |
dc.citation.volume | 36 | - |
dc.citation.number | 5 | - |
dc.citation.date | 2013 | - |
dc.citation.startPage | 840 | - |
dc.citation.endPage | 848 | - |
dc.identifier.bibliographicCitation | Journal of separation science, 36(5). : 840-848, 2013 | - |
dc.identifier.eissn | 1615-9314 | - |
dc.relation.journalid | J016159306 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.