Cited 0 times in
Simultaneous clinical monitoring of lactic acid, pyruvic acid and ketone bodies in plasma as methoxime/tert-butyldimethylsilyl derivatives by gas chromatography-mass spectrometry in selected ion monitoring mode.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Paik, MJ | - |
dc.contributor.author | Cho, EY | - |
dc.contributor.author | Kim, H | - |
dc.contributor.author | Kim, KR | - |
dc.contributor.author | Choi, S | - |
dc.contributor.author | Ahn, YH | - |
dc.contributor.author | Lee, G | - |
dc.date.accessioned | 2011-01-14T04:51:29Z | - |
dc.date.available | 2011-01-14T04:51:29Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 0269-3879 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/1149 | - |
dc.description.abstract | Simultaneous determination of lactic acid, pyruvic acid, 3-hydroxybutyric acid and acetoacetic acid for clinical monitoring of lactic acidosis and ketone body formation in human plasma (20 microL) was performed by gas chromatography-mass spectrometry in selected ion monitoring (SIM) mode after generating methoxime/tert-butyldimethylsilyl derivatives. All of the targeted carboxylic acids were detected by characteristic fragment ions, which permitted sensitive and selective identification in the presence of co-extracted free fatty acids and other acidic metabolites at much higher levels. The method was linear (r>or=0.9991), reproducible (% relative standard deviation=1.2-5.8), and accurate (% relative error=-7.2-7.6), with detection limits of 0.05-1.7 ng/mL. This rapid, accurate and selective method using minimal plasma samples (20 microL) is useful in the clinical monitoring of lactic acidosis and ketone body formation in plasma. | - |
dc.language.iso | en | - |
dc.subject.MESH | Gas Chromatography-Mass Spectrometry | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Ketone Bodies | - |
dc.subject.MESH | Lactic Acid | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Organosilicon Compounds | - |
dc.subject.MESH | Oximes | - |
dc.subject.MESH | Pyruvic Acid | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.title | Simultaneous clinical monitoring of lactic acid, pyruvic acid and ketone bodies in plasma as methoxime/tert-butyldimethylsilyl derivatives by gas chromatography-mass spectrometry in selected ion monitoring mode. | - |
dc.type | Article | - |
dc.identifier.pmid | 18254151 | - |
dc.contributor.affiliatedAuthor | 백, 만정 | - |
dc.contributor.affiliatedAuthor | 안, 영환 | - |
dc.contributor.affiliatedAuthor | 이, 광 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1002/bmc.966 | - |
dc.citation.title | Biomedical chromatography : BMC | - |
dc.citation.volume | 22 | - |
dc.citation.number | 5 | - |
dc.citation.date | 2008 | - |
dc.citation.startPage | 450 | - |
dc.citation.endPage | 453 | - |
dc.identifier.bibliographicCitation | Biomedical chromatography : BMC, 22(5). : 450-453, 2008 | - |
dc.identifier.eissn | 1099-0801 | - |
dc.relation.journalid | J002693879 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.