Cited 0 times in
Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway: A randomized noninferiority trial
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwak, HJ | - |
dc.contributor.author | Lee, SY | - |
dc.contributor.author | Lee, SY | - |
dc.contributor.author | Kim, YB | - |
dc.contributor.author | Kim, JY | - |
dc.date.accessioned | 2018-05-04T00:25:23Z | - |
dc.date.available | 2018-05-04T00:25:23Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0025-7974 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/14998 | - |
dc.description.abstract | BACKGROUND: During McGrath videolaryngoscope (VL) intubation, a styletted endotracheal tube maintaining an upward distal tip angle is recommended by some manufacturers. However, a styletted endotracheal tube can elicit rare but potentially serious complications. The purpose of this study was to demonstrate that a nonstyletted tube with exaggerated curvature would be noninferior to a styletted tube for orotracheal intubation using McGrath VL in patients with expected normal airway, by comparing the time to intubation and ease of intubation. METHODS: One hundred forty patients, ages 19 to 70 years (American Society of Anesthesiologists physical status I-II), undergoing tracheal intubation for elective surgery were randomly allocated to the nonstylet group (n = 70) or the stylet group (n = 70). Anesthesia induction consisted of propofol, remifentanil, and rocuronium. The primary outcome was time to intubation assessed by a blind observer. Cormack and Lehane glottic grade, easy of intubation, and intubation difficulty score (IDS) were also assessed. RESULTS: Median time to intubation [interquartile range] was not different between the nonstylet group and the stylet group (26 [24-32.5] s vs 27 [25-31] s, P = 0.937). There was no significant in median IDS between the nonstylet group and the stylet group (P = 0.695). CONCLUSION: This study shows that a nonstyletted endotracheal tube with exaggerated curvature has a similar performance to a styletted tube with a hockey-stick curvature during intubation using McGrath VL regarding time taken to successful intubation and easiness of intubation. | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Elective Surgical Procedures | - |
dc.subject.MESH | Equipment Design | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intubation, Intratracheal | - |
dc.subject.MESH | Laryngoscopy | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Video Recording | - |
dc.title | Intubation without use of stylet for McGrath videolaryngoscopy in patients with expected normal airway: A randomized noninferiority trial | - |
dc.type | Article | - |
dc.identifier.pmid | 27902612 | - |
dc.identifier.url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134778/ | - |
dc.contributor.affiliatedAuthor | 이, 숙영 | - |
dc.contributor.affiliatedAuthor | 김, 종엽 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1097/MD.0000000000005498 | - |
dc.citation.title | Medicine | - |
dc.citation.volume | 95 | - |
dc.citation.number | 48 | - |
dc.citation.date | 2016 | - |
dc.citation.startPage | e5498 | - |
dc.citation.endPage | e5498 | - |
dc.identifier.bibliographicCitation | Medicine, 95(48). : e5498-e5498, 2016 | - |
dc.identifier.eissn | 1536-5964 | - |
dc.relation.journalid | J000257974 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.