Cited 0 times in Scipus Cited Count

Provider risk factors for medication administration error alerts: analyses of a large-scale closed-loop medication administration system using RFID and barcode

DC Field Value Language
dc.contributor.authorHwang, Y-
dc.contributor.authorYoon, D-
dc.contributor.authorAhn, EK-
dc.contributor.authorHwang, H-
dc.contributor.authorPark, RW-
dc.date.accessioned2018-05-04T00:26:13Z-
dc.date.available2018-05-04T00:26:13Z-
dc.date.issued2016-
dc.identifier.issn1053-8569-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/15107-
dc.description.abstractPURPOSE: To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large-scale medication administration data and related error logs automatically recorded in a closed-loop medication administration system using radio-frequency identification and barcodes. METHODS: The subject hospital adopted a closed-loop medication administration system. All medication administrations in the general wards were automatically recorded in real-time using radio-frequency identification, barcodes, and hand-held point-of-care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis. RESULTS: A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient-years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non-standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515-1.604], emergency order (OR 1.527, 95%CI 1.464-1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992-0.993). Medication route, nurse's employment duration, and working schedule were also significantly related. CONCLUSION: The MAE alert rate was 1.22% over the 1-year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real-time closed-loop medication administration system contributed to improving patient safety by preventing potential MAEs. Copyright (c) 2016 John Wiley & Sons, Ltd.-
dc.language.isoen-
dc.subject.MESHAutomatic Data Processing-
dc.subject.MESHHumans-
dc.subject.MESHLogistic Models-
dc.subject.MESHMedical Order Entry Systems-
dc.subject.MESHMedication Errors-
dc.subject.MESHMedication Systems, Hospital-
dc.subject.MESHNurses-
dc.subject.MESHPharmaceutical Preparations-
dc.subject.MESHPoint-of-Care Systems-
dc.subject.MESHRadio Frequency Identification Device-
dc.subject.MESHRisk Factors-
dc.subject.MESHTime Factors-
dc.subject.MESHWork Schedule Tolerance-
dc.titleProvider risk factors for medication administration error alerts: analyses of a large-scale closed-loop medication administration system using RFID and barcode-
dc.typeArticle-
dc.identifier.pmid27465030-
dc.contributor.affiliatedAuthor윤, 덕용-
dc.contributor.affiliatedAuthor박, 래웅-
dc.type.localJournal Papers-
dc.identifier.doi10.1002/pds.4068-
dc.citation.titlePharmacoepidemiology and drug safety-
dc.citation.volume25-
dc.citation.number12-
dc.citation.date2016-
dc.citation.startPage1387-
dc.citation.endPage1396-
dc.identifier.bibliographicCitationPharmacoepidemiology and drug safety, 25(12). : 1387-1396, 2016-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1099-1557-
dc.relation.journalidJ010538569-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Biomedical Informatics
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse