Cited 0 times in
Diagnostic role of cone beam computed tomography for the position of straight array
DC Field | Value | Language |
---|---|---|
dc.contributor.author | An, SY | - |
dc.contributor.author | An, CH | - |
dc.contributor.author | Lee, KY | - |
dc.contributor.author | Jang, JH | - |
dc.contributor.author | Choung, YH | - |
dc.contributor.author | Lee, SH | - |
dc.date.accessioned | 2019-11-13T04:27:58Z | - |
dc.date.available | 2019-11-13T04:27:58Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 0001-6489 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/17640 | - |
dc.description.abstract | OBJECTIVE: To assess the usefulness of cone beam computed tomography (CBCT) for characterizing electrode insertion and evaluate the influence of electrode insertion status on post-cochlear implantation (CI) outcomes.
DESIGN: Twenty-six ears with post-CI CBCT scans were included. The devices were MED-EL Flex28 (n = 21) and Nucleus slim straight (n = 5). The parameters including cochlear duct length (CDL), insertion depth angle (IDA), insertion length of electrode (IL), and cochlear coverage (CC) were analyzed and compared with aided pure-tone threshold (PTA) with implant in free field, and open-set sentence score. RESULTS: The mean CDL was 36.8 +/- 1.4 mm. Electrode array was dislocated into scala tympani in two ears. The mean IL and IDA were 26.5 +/- 1.9 mm and 541.4 +/- 70.2 degrees . The mean linear CC (IL/CDL, 0.73 +/- 0.06) was larger than the mean angular CC (IDA/900, 0.60 +/- 0.08). The CBCT parameters showed correlation one another. While the aided pure-tone threshold was correlated with IL and IDA, there were no significant correlations in the open-set sentence score. For the postlingually deaf patients with single electrode (Flex 28), the sentence score had no significant correlation and the aided PTA was positively correlated with IL (R = 0.517, p = .028). CONCLUSIONS: This study validated the CBCT evaluating the electrode array position. The CBCT could be helpful for the preoperative selection of the optimal array and prediction of the CC. | - |
dc.format | application/pdf | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Cochlea | - |
dc.subject.MESH | Cochlear Implantation | - |
dc.subject.MESH | Cone-Beam Computed Tomography | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Young Adult | - |
dc.title | Diagnostic role of cone beam computed tomography for the position of straight array | - |
dc.type | Article | - |
dc.identifier.pmid | 29172857 | - |
dc.subject.keyword | Cochlear implants | - |
dc.subject.keyword | cochlear duct | - |
dc.subject.keyword | cone-beam computed tomography | - |
dc.subject.keyword | implanted electrode | - |
dc.contributor.affiliatedAuthor | 장, 정훈 | - |
dc.contributor.affiliatedAuthor | 정, 연훈 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1080/00016489.2017.1404639 | - |
dc.citation.title | Acta oto-laryngologica | - |
dc.citation.volume | 138 | - |
dc.citation.number | 4 | - |
dc.citation.date | 2018 | - |
dc.citation.startPage | 375 | - |
dc.citation.endPage | 381 | - |
dc.identifier.bibliographicCitation | Acta oto-laryngologica, 138(4). : 375-381, 2018 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.identifier.eissn | 1651-2251 | - |
dc.relation.journalid | J000016489 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.