Cited 0 times in
Clinical Value of Measurement of Internal Auditory Canal in Pediatric Cochlear Implantation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, H | - |
dc.contributor.author | Kim, DY | - |
dc.contributor.author | Ha, EJ | - |
dc.contributor.author | Park, HY | - |
dc.date.accessioned | 2020-10-21T07:20:20Z | - |
dc.date.available | 2020-10-21T07:20:20Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0003-4894 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/18737 | - |
dc.description.abstract | OBJECTIVES: The aims of this study were to clarify the clinical value of the bony cochlear nerve canal (BCNC) and internal auditory canal (IAC) in children with bilateral sensorineural hearing loss (b-SNHL) and to reveal the correlation between these parameters and outcomes after cochlear implantation (CI).
METHODS: Ninety-four ears with b-SNHL that received CI and 100 ears with normal hearing were enrolled. Parameters of IAC and pre- and post-CI categories of auditory performance scores were analyzed. RESULTS: The width of the BCNC and the width, height, and length of the IAC were shorter in the b-SNHL group. BCNC and IAC width were associated with b-SNHL. The calculated cutoff values for BCNC and IAC width were 2.055 mm in the BCNC and 4.245 mm in the IAC, setting the sensitivity to 90%. Patients with narrow BCNCs and IACs had significantly worse post-CI auditory performance. CONCLUSIONS: BCNC and IAC widths were narrower in children with b-SNHL than in normal-hearing children. Narrow BCNC and IAC width had a negative impact on post-CI outcomes. The proposed cutoff values for BCNC and IAC width were meaningful when predicting the auditory outcome after CI, especially considering both. | - |
dc.language.iso | en | - |
dc.subject.MESH | Age Factors | - |
dc.subject.MESH | Auditory Threshold | - |
dc.subject.MESH | Case-Control Studies | - |
dc.subject.MESH | Child | - |
dc.subject.MESH | Child, Preschool | - |
dc.subject.MESH | Cochlear Implantation | - |
dc.subject.MESH | Cochlear Nerve | - |
dc.subject.MESH | Ear, Inner | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Hearing Loss, Sensorineural | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Predictive Value of Tests | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Clinical Value of Measurement of Internal Auditory Canal in Pediatric Cochlear Implantation | - |
dc.type | Article | - |
dc.identifier.pmid | 31092027 | - |
dc.subject.keyword | cochlear implantation | - |
dc.subject.keyword | inner ear | - |
dc.subject.keyword | sensorineural hearing loss | - |
dc.subject.keyword | temporal bone | - |
dc.contributor.affiliatedAuthor | 김, 한태 | - |
dc.contributor.affiliatedAuthor | 하, 은주 | - |
dc.contributor.affiliatedAuthor | 박, 헌이 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1177/0003489419835234 | - |
dc.citation.title | The Annals of otology, rhinology, and laryngology | - |
dc.citation.volume | 128 | - |
dc.citation.number | 6 | - |
dc.citation.date | 2019 | - |
dc.citation.startPage | 61S | - |
dc.citation.endPage | 68S | - |
dc.identifier.bibliographicCitation | The Annals of otology, rhinology, and laryngology, 128(6). : 61S-68S, 2019 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.identifier.eissn | 1943-572X | - |
dc.relation.journalid | J000034894 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.