Cited 0 times in Scipus Cited Count

A 3D Microscaffold Cochlear Electrode Array for Steroid Elution

DC Field Value Language
dc.contributor.authorJang, J-
dc.contributor.authorKim, JY-
dc.contributor.authorKim, YC-
dc.contributor.authorKim, S-
dc.contributor.authorChou, N-
dc.contributor.authorLee, S-
dc.contributor.authorChoung, YH-
dc.contributor.authorKim, S-
dc.contributor.authorBrugger, J-
dc.contributor.authorChoi, H-
dc.contributor.authorJang, JH-
dc.date.accessioned2020-11-17T05:25:08Z-
dc.date.available2020-11-17T05:25:08Z-
dc.date.issued2019-
dc.identifier.issn2192-2640-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/19009-
dc.description.abstractIn cochlear implants, the electrode insertion trauma during surgery can cause damage residual hearing. Preserving the residual hearing is an important challenge and the localized administration of drugs, such as steroids, is one of the most promising ways, but remains a challenge. Here, a microscaffold cochlear electrode array (MiSCEA) consisting of a microfabricated flexible electrode array and a 3D microscaffold for steroid reservoir is reported. The MiSCEA without loaded drug is tested by measuring the electrically evoked auditory brainstem response of the cochlea in guinea pigs (n = 4). The scaffold is then coated with steroid (dexamethasone) encapsulated in polylactic-co-glycolic acid and the continuous release of the steroid into artificial perilymph during six weeks is monitored. The steroid-containing scaffolds are then implanted into guinea pigs (n = 4) and threshold shifts are analyzed for four weeks by measuring the acoustically evoked auditory brainstem response. The threshold shifts tend to be lower in the group implanted with the steroid-containing MiSCEAs. The feasibility of 3D MiSCEA opens up the development of potential next-generation cochlear electrode with improved steroid release dynamics into cochlea.-
dc.language.isoen-
dc.subject.MESHAnimals-
dc.subject.MESHCalibration-
dc.subject.MESHCochlea-
dc.subject.MESHCochlear Implantation-
dc.subject.MESHCochlear Implants-
dc.subject.MESHDexamethasone-
dc.subject.MESHDrug Delivery Systems-
dc.subject.MESHElectrodes, Implanted-
dc.subject.MESHEvoked Potentials, Auditory, Brain Stem-
dc.subject.MESHGuinea Pigs-
dc.subject.MESHPolylactic Acid-Polyglycolic Acid Copolymer-
dc.subject.MESHPrinting, Three-Dimensional-
dc.subject.MESHSteroids-
dc.subject.MESHTissue Scaffolds-
dc.titleA 3D Microscaffold Cochlear Electrode Array for Steroid Elution-
dc.typeArticle-
dc.identifier.pmid31532887-
dc.subject.keyword3D scaffolds-
dc.subject.keywordMEMS electrode arrays-
dc.subject.keywordauditory brainstem response-
dc.subject.keywordcochlear implants-
dc.subject.keyworddexamethasone-
dc.contributor.affiliatedAuthor정, 연훈-
dc.contributor.affiliatedAuthor장, 정훈-
dc.type.localJournal Papers-
dc.identifier.doi10.1002/adhm.201900379-
dc.citation.titleAdvanced healthcare materials-
dc.citation.volume8-
dc.citation.number20-
dc.citation.date2019-
dc.citation.startPagee1900379-
dc.citation.endPagee1900379-
dc.identifier.bibliographicCitationAdvanced healthcare materials, 8(20). : e1900379-e1900379, 2019-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn2192-2659-
dc.relation.journalidJ021922640-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Otolaryngology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse