Cited 0 times in Scipus Cited Count

Effect of distal protection device on the microvascular integrity in acute myocardial infarction during primary percutaneous coronary intervention.

DC Field Value Language
dc.contributor.authorYoon, MH-
dc.contributor.authorTahk, SJ-
dc.contributor.authorChoi, SY-
dc.contributor.authorChoi, TY-
dc.contributor.authorChoi, BJ-
dc.contributor.authorChoi, JH-
dc.contributor.authorYoo, SY-
dc.contributor.authorAhn, SG-
dc.contributor.authorZheng, ZG-
dc.contributor.authorHwang, GS-
dc.contributor.authorShin, JH-
dc.date.accessioned2011-03-28T05:49:51Z-
dc.date.available2011-03-28T05:49:51Z-
dc.date.issued2006-
dc.identifier.issn1346-9843-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/1981-
dc.description.abstractBACKGROUND: The use of a distal protection device during primary percutaneous coronary intervention (PCI) in acute myocardial infarction (AMI) may preserve the microvascular integrity of the myocardium.



METHODS AND RESULTS: A total of 58 consecutive patients with AMI, who had undergone primary PCI within 24 h after onset, were enrolled (30 patients with the PercuSurge GuardWire System, 28 without). The coronary flow velocity reserve was not different between the 2 groups. In patients with a distal protection device, the post-PCI Thrombolysis In Myocardial Infarction myocardial perfusion grades (TMP) were more favorable (TMP 0/1: 13.3%, TMP 2: 23.3%, TMP 3: 63.4% vs TMP 0/1: 35.7%, TMP 2: 35.7%, TMP 3: 28.6%, p=0.023). These patients also exhibited lower basal and hyperemic microvascular resistance index levels (4.33+/-2.22 vs 5.55+/-2.36 mmHg . cm(-1) . s, p=0.047; 2.39+/-1.40 vs 3.14+/-1.36 mmHg . cm(-1) . s, p=0.045, respectively), and longer basal diastolic deceleration time (679+/-273 vs 519+/-289 ms, p=0.035) after PCI.



CONCLUSION: Distal protection with the PercuSurge GuardWire system may effectively preserve the microvascular integrity of the myocardium during primary PCI in AMI patients.
-
dc.language.isoen-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAngioplasty, Balloon, Coronary-
dc.subject.MESHBlood Flow Velocity-
dc.subject.MESHCoronary Vessels-
dc.subject.MESHEquipment and Supplies-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMicrocirculation-
dc.subject.MESHMiddle Aged-
dc.subject.MESHMyocardial Infarction-
dc.titleEffect of distal protection device on the microvascular integrity in acute myocardial infarction during primary percutaneous coronary intervention.-
dc.typeArticle-
dc.identifier.pmid16998260-
dc.identifier.urlhttp://joi.jlc.jst.go.jp/JST.JSTAGE/circj/70.1284?from=PubMed-
dc.contributor.affiliatedAuthor윤, 명호-
dc.contributor.affiliatedAuthor탁, 승제-
dc.contributor.affiliatedAuthor최, 소연-
dc.contributor.affiliatedAuthor최, 병주-
dc.contributor.affiliatedAuthor황, 교승-
dc.contributor.affiliatedAuthor신, 준한-
dc.type.localJournal Papers-
dc.citation.titleCirculation journal-
dc.citation.volume70-
dc.citation.number10-
dc.citation.date2006-
dc.citation.startPage1284-
dc.citation.endPage1289-
dc.identifier.bibliographicCitationCirculation journal, 70(10). : 1284-1289, 2006-
dc.identifier.eissn1347-4820-
dc.relation.journalidJ013469843-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Cardiology
Files in This Item:
16998260.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse