Cited 0 times in Scipus Cited Count

Pressure-controlled versus volume-controlled ventilation during one-lung ventilation in the prone position for robot-assisted esophagectomy.

DC Field Value Language
dc.contributor.authorChoi, YS-
dc.contributor.authorShim, JK-
dc.contributor.authorNa, S-
dc.contributor.authorHong, SB-
dc.contributor.authorHong, YW-
dc.contributor.authorOh, YJ-
dc.date.accessioned2010-11-22T04:53:00Z-
dc.date.available2010-11-22T04:53:00Z-
dc.date.issued2009-
dc.identifier.issn0930-2794-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/213-
dc.description.abstractBACKGROUND: The prone position during robotic esophageal mobilization for minimally invasive esophagectomy (MIE) provides several advantages with regards to operative times, surgeon ergonomics, and surgical view; however, this technique requires one-lung ventilation (OLV). There are no guidelines about ventilatory modes during OLV in the prone position. We investigated the effects of volume-controlled (VCV) and pressure-controlled ventilation (PCV) on oxygenation and intrapulmonary shunt during OLV in the prone position in patients who underwent robot-assisted esophagectomy.



METHODS: Eighteen patients, no major obstructive or restrictive pulmonary disease, were allocated randomly to one of two groups. In the first group (n = 9), OLV was started by VCV and the ventilator was switched to PCV after 30 minutes. In the second group (n = 9), the modes of ventilation were performed in the opposite order in the prone position. Hemodynamic and respiratory variables were obtained during OLV at the end of each ventilatory mode.



RESULTS: There were no significant differences in arterial oxygen tension (PaO(2)), airway pressures, dynamic lung compliance, or physiologic dead space (Vd/Vt) during OLV between PCV and VCV in the prone position. Intrapulmonary shunt (Qs/Qt) was significantly lower with VCV than with PCV during OLV in the prone position (p = 0.044).



CONCLUSION: PCV provides no advantages compared with VCV with regard to respiratory and hemodynamic variables during OLV in the prone position. Either ventilatory mode can be safely used for patients who undergo robot-assisted esophagectomy and who have normal body mass index and preserved pulmonary function.
-
dc.formattext/plain-
dc.language.isoen-
dc.subject.MESHAnalysis of Variance-
dc.subject.MESHEsophagectomy-
dc.subject.MESHEsophagoscopy-
dc.subject.MESHFemale-
dc.subject.MESHHemodynamics-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPressure-
dc.subject.MESHProne Position-
dc.subject.MESHProspective Studies-
dc.subject.MESHRespiration, Artificial-
dc.subject.MESHRespiratory Function Tests-
dc.subject.MESHRobotics-
dc.subject.MESHSurgical Procedures, Minimally Invasive-
dc.titlePressure-controlled versus volume-controlled ventilation during one-lung ventilation in the prone position for robot-assisted esophagectomy.-
dc.typeArticle-
dc.identifier.pmid19184209-
dc.contributor.affiliatedAuthor홍, 용우-
dc.type.localJournal Papers-
dc.identifier.doi10.1007/s00464-008-0310-5-
dc.citation.titleSurgical endoscopy-
dc.citation.volume23-
dc.citation.number10-
dc.citation.date2009-
dc.citation.startPage2286-
dc.citation.endPage2291-
dc.identifier.bibliographicCitationSurgical endoscopy, 23(10). : 2286-2291, 2009-
dc.identifier.eissn1432-2218-
dc.relation.journalidJ009302794-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Anesthesiology & Pain Medicine
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse