AIM: To investigate the best cut-off percentage volume of delayed kinetics using magnetic resonance imaging (MRI) with computer-aided diagnosis (CAD) to reduce unnecessary biopsies in patients with newly diagnosed breast cancer.

MATERIALS AND METHODS: Between January 2017 and December 2018, 94 malignant and 56 benign masses were analysed using MRI CAD. All malignant and benign masses measured <2 cm and were confirmed histopathologically. The optimal cut-off values for washout, plateau, and persistent components were determined using the maximum Youden Index. The positive predictive value (PPV) was analysed using morphological descriptors and combining the percentage volume of delayed kinetics.

RESULTS: The area under the curve (AUC) was highest at 26% (AUC=0.697). When the persistent 26% was applied to C4a, and the PPV increased from 46.77% to 61.36% with five false-negative cases when applied to C4a and C4b.

CONCLUSION: The percentage volume of delayed kinetics has the potential to improve the PPV of breast MRI. When suspicious masses <2 cm do not show
MeSH

DOI
10.1016/j.crad.2020.08.005
PMID
32888654
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Ajou Authors
강, 두경  |  김, 태희  |  하, 태양
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse