Burst-shot infrared digital photography to determine scotopic pupil diameter.

Authors
Yang, H  | Lee, M | Kim, JB | Ahn, J
Citation
Journal of cataract and refractive surgery, 32(12). : 2113-2117, 2006
Journal Title
Journal of cataract and refractive surgery
ISSN
0886-33501873-4502
Abstract
PURPOSE: To evaluate the usefulness of infrared digital photography for determining scotopic pupil size by comparing infrared digital photography with a Colvard pupillometer (Oasis Medical).



SETTING: Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea.



METHODS: Scotopic pupil size in 50 eyes of 25 healthy individuals was measured with a Colvard pupillometer and a digital camera (DSC-F828) using infrared burst shots after 5 minutes of dark adaptation. Measurements were performed by 2 independent examiners (E1 and E2). The digital photograph images were read using the ruler function of Adobe Photoshop 7.0 by 2 independent readers (R1 and R2). Agreement and repeatability were analyzed using the comparison method described by Bland and Altman.



RESULTS: The mean scotopic pupil diameter measured using the Colvard pupillometer was 6.69 mm +/- 0.78 (SD) (E1) and 6.70 +/- 0.71 mm (E2). The mean scotopic pupil diameter measured from the digital photograph images was 6.67 +/- 0.75 mm (E1) and 6.66 +/- 0.78 mm (E2). The mean difference between E1 and E2 with both devices was small; however, the result with the infrared digital camera was marginally smaller than with the Colvard pupillometer. The limits of agreement were -0.01 +/- 0.70 mm with the Colvard pupillometer and 0.01 +/- 0.20 mm with the digital photograph image. The digital photograph image showed better agreement. The coefficient of interrater repeatability was smaller for the digital photograph image (0.39) than for the Colvard pupillometer (0.70).



CONCLUSIONS: Scotopic pupil measurement using an infrared digital camera with a burst shot had good agreement with the Colvard pupillometer and better repeatability. The infrared digital camera is less expensive, and pupil unrest can be overcome by taking serial images.
MeSH

DOI
10.1016/j.jcrs.2006.06.039
PMID
17137993
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Ophthalmology
Ajou Authors
안, 재홍  |  양, 홍석
Full Text Link
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse