Cited 0 times in Scipus Cited Count

Development of Volumetric Independent Dose Calculation System for Verification of the Treatment Plan in Image-Guided Adaptive Brachytherapy

DC Field Value Language
dc.contributor.authorKang, SW-
dc.contributor.authorChung, JB-
dc.contributor.authorKim, KH-
dc.contributor.authorPark, JY-
dc.contributor.authorPark, HJ-
dc.contributor.authorCho, W-
dc.contributor.authorOlberg, S-
dc.contributor.authorSuh, TS-
dc.contributor.authorPark, JC-
dc.date.accessioned2022-11-29T01:43:24Z-
dc.date.available2022-11-29T01:43:24Z-
dc.date.issued2020-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/22980-
dc.description.abstractPURPOSE: This study aimed to develop a volumetric independent dose calculation (vIDC) system for verification of the treatment plan in image-guided adaptive brachytherapy (IGABT) and to evaluate the feasibility of the vIDC in clinical practice with simulated cases. METHODS: The vIDC is based on the formalism of TG-43. Four simulated cases of cervical cancer were selected to retrospectively evaluate the dose distributions in IGABT. Some reference point doses, such as points A and B and rectal points, were calculated by vIDC using absolute coordinate. The 3D dose volume was also calculated to acquire dose-volume histograms (DVHs) with grid resolutions of 1.0 x 1.0 (G1.0), 2.5 x 2.5 (G2.5), and 0.5 x 0.5 mm(2) (G0.5). Dosimetric parameters such as D90% and D2cc doses covering 90% of the high-risk critical target volume (HR-CTV) and 2 cc of the organs at risk (OARs) were obtained from DVHs. D90% also converted to equivalent dose in 2-Gy fractions (EQD2) to produce the same radiobiological effect as external beam radiotherapy. In addition, D90% was obtained in two types with or without the applicator volume to confirm the effect of the applicator itself. Validation of the vIDC was also performed using gamma evaluation by comparison with Monte Carlo simulation. RESULTS: The average percentage difference of point doses was <2.28%. The DVHs for the HR-CTV and OARs showed no significant differences between the vIDC and the treatment planning system (TPS). Without considering the applicator volume, the D90% of the HR-CTV calculated by the vIDC decreases with a decreasing calculated dose-grid size (32.4, 5.65, and -2.20 cGy in G2.5, G1.0, and G0.5, respectively). The overall D90% is higher when considering the applicator volume. The converted D90% by EQD2 ranged from -1.29 to 1.00%. The D2cc of the OARs showed that the averaged dose deviation is <10 cGy regardless of the dose-grid size. Based on gamma analysis, the passing rate was 98.81% for 3%/3-mm criteria. CONCLUSION: The vIDC was developed as an independent dose verification system for verification of the treatment plan in IGABT. We confirmed that the vIDC is suitable for second-check dose validation of the TPS under various conditions.-
dc.language.isoen-
dc.titleDevelopment of Volumetric Independent Dose Calculation System for Verification of the Treatment Plan in Image-Guided Adaptive Brachytherapy-
dc.typeArticle-
dc.identifier.pmid32477931-
dc.identifier.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7237701-
dc.subject.keywordindependent dose calculation system-
dc.subject.keywordimage-guided adaptive brachytherapy-
dc.subject.keywordAmerican Association of Physicists in Medicine Task Group 43-
dc.subject.keyworddose grid-
dc.subject.keywordequivalent dose in 2-Gy fractions-
dc.contributor.affiliatedAuthorPark, HJ-
dc.type.localJournal Papers-
dc.identifier.doi10.3389/fonc.2020.00609-
dc.citation.titleFrontiers in oncology-
dc.citation.volume10-
dc.citation.date2020-
dc.citation.startPage609-
dc.citation.endPage609-
dc.identifier.bibliographicCitationFrontiers in oncology, 10. : 609-609, 2020-
dc.identifier.eissn2234-943X-
dc.relation.journalidJ02234943X-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiation Oncology
Files in This Item:
32477931.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse