dc.description.abstract | Background: The depth of bolt in Femoral neck system (FNS, DePuy Synthes, Oberdorf, Switzerland) is difficult to finely control as the length of the bolt is in units of 5 mm. Thus, this study introduces a method to control the depth of FNS bolt in analogue scale in patients with femoral neck fracture. Methods: By the technique of control of reaming and retraction of bolt, the tip of implant could be positioned close to subchondral bone without harming it. The position of implant tip in four cases in which the introduced technique was applied was compared to that of eight cases where the standard technique was performed. Results: The average tip-apex distance measured in the cases that underwent surgery using the suggested technique in this study was statistically significantly shorter than that measured in the cases that underwent surgery under manufacturer guidelines. Conclusion: Even though the bolt of FNS is manufactured in the unit of 5 mm, the technique proposed in this study helps surgeons to adjust the depth of bolt for the fixation of femoral neck fracture using FNS. | - |
dc.language.iso | en | - |
dc.subject.MESH | Bone Screws | - |
dc.subject.MESH | Femoral Fractures | - |
dc.subject.MESH | Femoral Neck Fractures | - |
dc.subject.MESH | Femur Neck | - |
dc.subject.MESH | Fracture Fixation, Internal | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Switzerland | - |
dc.title | Improved control over implant anchorage under the use of the femoral neck system for fixation of femoral neck fractures: a technical note | - |
dc.type | Article | - |
dc.identifier.pmid | 34256741 | - |
dc.identifier.url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8278696/ | - |
dc.subject.keyword | Femoral neck fracture | - |
dc.subject.keyword | Femoral neck system | - |
dc.subject.keyword | Fixation | - |
dc.subject.keyword | Hip | - |
dc.subject.keyword | Treatment | - |
dc.contributor.affiliatedAuthor | Kim, JT | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1186/s12891-021-04497-x | - |
dc.citation.title | BMC musculoskeletal disorders | - |
dc.citation.volume | 22 | - |
dc.citation.number | 1 | - |
dc.citation.date | 2021 | - |
dc.citation.startPage | 621 | - |
dc.citation.endPage | 621 | - |
dc.identifier.bibliographicCitation | BMC musculoskeletal disorders, 22(1). : 621-621, 2021 | - |
dc.identifier.eissn | 1471-2474 | - |
dc.relation.journalid | J014712474 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.