Cited 0 times in Scipus Cited Count

Touchless control of picture archiving and communication system in operating room environment: A comparative study of input methods

DC Field Value Language
dc.contributor.authorKim, JT-
dc.contributor.authorCha, YH-
dc.contributor.authorYoo, JI-
dc.contributor.authorPark, CH-
dc.date.accessioned2023-01-26T06:10:32Z-
dc.date.available2023-01-26T06:10:32Z-
dc.date.issued2021-
dc.identifier.issn2005-291X-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/24130-
dc.description.abstractBackground: The advancement of computer information technology would maximize its potential in operating rooms with touch-less input devices. A picture archiving and communication system (PACS) was compared with a touchless input device (LMC-GW), relaying to another person to control a mouse through verbal guidance, and directly controlling a mouse. Methods: Participants (n = 34; mean age, 29.6 years) were prospectively enrolled and given nine scenarios to compare the three methods. Each scenario consisted of eight tasks, which required 6 essential functions of PACS. Time elapsed and measurement values were recorded for objective evaluation, while subjective evaluation was conducted with a questionnaire. Results: In all 8 tasks, manipulation using the mouse took significantly less time than the other methods (all p < 0.05). Study se-lection, panning, zooming, scrolling, distance measuring, and leg length measurement took significantly less time when LMC-GW was used compared to relaying to another person (all p < 0.01), whereas there were no significant differences in time required for measuring the angles and windowing. Although the touchless input device provided higher accessibility and lower contamination risk, it was more difficult to handle than the other input methods (all p < 0.01). Conclusions: The touchless input device provided superior or equal performance to the method of verbal instruction in the environment of operating room. Surgeons agreed that the device would be helpful for manipulating PACS in operating rooms with less contamination risk and disturbance of workflow. The touchless input device can be an alternative option for direct manipulation of a mouse in operation rooms in the future.-
dc.language.isoen-
dc.subject.MESHAdult-
dc.subject.MESHComputer Peripherals-
dc.subject.MESHComputer Systems-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHOperating Rooms-
dc.subject.MESHProspective Studies-
dc.subject.MESHRadiology Information Systems-
dc.subject.MESHUser-Computer Interface-
dc.titleTouchless control of picture archiving and communication system in operating room environment: A comparative study of input methods-
dc.typeArticle-
dc.identifier.pmid34484637-
dc.identifier.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8380534/-
dc.subject.keywordMouse-
dc.subject.keywordOperating room-
dc.subject.keywordPicture archiving and communication system-
dc.subject.keywordTouchless-
dc.contributor.affiliatedAuthorKim, JT-
dc.type.localJournal Papers-
dc.identifier.doi10.4055/cios20004-
dc.citation.titleClinics in orthopedic surgery-
dc.citation.volume13-
dc.citation.number3-
dc.citation.date2021-
dc.citation.startPage436-
dc.citation.endPage446-
dc.identifier.bibliographicCitationClinics in orthopedic surgery, 13(3). : 436-446, 2021-
dc.identifier.eissn2005-4408-
dc.relation.journalidJ02005291X-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Orthopedic Surgery
Files in This Item:
34484637.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse