Cited 0 times in Scipus Cited Count

Intravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.

DC Field Value Language
dc.contributor.authorHe, Y-
dc.contributor.authorMaehara, A-
dc.contributor.authorMintz, GS-
dc.contributor.authorBharaj, H-
dc.contributor.authorCastellanos, C-
dc.contributor.authorKesanakurthy, S-
dc.contributor.authorWu, X-
dc.contributor.authorGuo, N-
dc.contributor.authorChoi, SY-
dc.contributor.authorLeon, MB-
dc.contributor.authorStone, GW-
dc.contributor.authorMehran, R-
dc.contributor.authorRabbani, LE-
dc.contributor.authorMoses, JW-
dc.date.accessioned2011-05-13T05:32:40Z-
dc.date.available2011-05-13T05:32:40Z-
dc.date.issued2010-
dc.identifier.issn0002-9149-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/2586-
dc.description.abstractIt is not clear whether the thin struts and different alloy of a cobalt chromium stent will cause greater acute stent recoil compared to conventional stainless steel stents. We used postintervention intravascular ultrasound (IVUS) examinations to study 99 patients with 116 stented lesions: 61 Xience/Promus stents (cobalt chromium stent group) and 27 Taxus Liberté and 28 Cypher stents (stainless steel stent group). The IVUS images were obtained before and immediately after stent implantation with only the stent-delivery balloon. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was the measure of acute stent recoil and expansion. The baseline patient characteristics, lesion morphology, and procedural details were comparable between the 2 groups. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was 0.74 versus 0.73 (p = 0.57) and 0.63 versus 0.63 (p = 0.69), respectively, for the cobalt chromium and stainless steel stents. In conclusion, the acute performance of Xience/Promus was similar to that of previous stainless steel stents, and the thinner cobalt chromium metallic platform did not compromise the radial strength of the stent.-
dc.language.isoen-
dc.subject.MESHAged-
dc.subject.MESHAngioplasty, Balloon, Coronary-
dc.subject.MESHChromium Alloys-
dc.subject.MESHCoated Materials, Biocompatible-
dc.subject.MESHCoronary Stenosis-
dc.subject.MESHCoronary Vessels-
dc.subject.MESHDrug-Eluting Stents-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHPostoperative Period-
dc.subject.MESHProsthesis Design-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHStainless Steel-
dc.subject.MESHUltrasonography, Interventional-
dc.titleIntravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.-
dc.typeArticle-
dc.identifier.pmid20403478-
dc.identifier.urlhttp://linkinghub.elsevier.com/retrieve/pii/S0002-9149(09)02917-8-
dc.contributor.affiliatedAuthor최, 소연-
dc.type.localJournal Papers-
dc.identifier.doi10.1016/j.amjcard.2009.12.042-
dc.citation.titleThe American journal of cardiology-
dc.citation.volume105-
dc.citation.number9-
dc.citation.date2010-
dc.citation.startPage1272-
dc.citation.endPage1275-
dc.identifier.bibliographicCitationThe American journal of cardiology, 105(9). : 1272-1275, 2010-
dc.identifier.eissn1879-1913-
dc.relation.journalidJ000029149-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Cardiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse