Modified design of x-ray protective clothing to enhance radiation protection for interventional radiologists

Authors
Choi, TW  | Chung, JW | Kwon, Y
Citation
Medical physics, 50(6). : 3825-3832, 2023
Journal Title
Medical physics
ISSN
0094-24052473-4209
Abstract
Background: In interventional radiology procedures, the operator typically stands on the right side of the patient's right thigh to manipulate devices through the femoral sheath. Because the standard x-ray protective clothing is designed as sleeveless and scatter radiations from the patient are mainly incident from the left-anterior direction to the operator, the arm hole of the clothing may be a significant unprotected area, contributing to an increase in the operator's organ doses and effective dose. Purpose: This study aimed to compare the organ doses and effective dose received by the interventional radiologist when wearing the standard x-ray protective clothing and when wearing the modified clothing with an additional shoulder guard. Methods: The experimental setup aimed to simulate actual clinical practice in interventional radiology. The patient phantom was located at the beam center to generate scatter radiation. An adult female anthropomorphic phantom loaded with 126 nanoDots (Landauer Inc., Glenwood, IL) was used to measure organ and effective doses to the operator. The standard wrap-around type x-ray protective clothing offered 0.25-mm lead-equivalent protection, and the frontal overlap area offered 0.50-mm lead-equivalent protection. The shoulder guard was custom-made with a material providing x-ray protection equivalent to lead of 0.50 mm thickness. The organ and effective doses were compared between the operator wearing the standard protective clothing and the one wearing the modified clothing with a shoulder guard. Results: After adding the shoulder guard, doses to the lungs, bone marrow, and esophagus decreased by 81.9%, 58.6%, and 58.7%, respectively, and the effective dose to the operator decreased by 47.7%. Conclusions: Widespread use of modified x-ray protective clothing with shoulder guards can significantly decrease the overall occupational radiation risk in interventional radiology.
Keywords

MeSH

DOI
10.1002/mp.16309
PMID
36794321
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Ajou Authors
최, 태원
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse