Cited 0 times in Scipus Cited Count

Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists

Authors
Kim, YS | Lee, SH | Kim, SY | Kim, ES | Park, AR | Chang, JM | Park, VY | Yoon, JH | Kang, BJ | Yun, B | Kim, TH  | Ko, ES | Chu, AJ | Kim, JY | Youn, I | Chae, EY | Choi, WJ | Kim, HJ | Kang, SH | Ha, SM | Moon, WK
Citation
Korean journal of radiology, 25(1). : 11-23, 2024
Journal Title
Korean journal of radiology
ISSN
1229-69292005-8330
Abstract
Objective: To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). Materials and Methods: A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive. The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). Results: Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4–79.9), 90.8% (95% CI: 85.6–94.2), and 83.5% (95% CI: 78.6–87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8–97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9–89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1–79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52–0.63) before training and 0.68 (95% CI: 0.62–0.74) after training, with a difference of 0.11 (95% CI: 0.02–0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69–0.74) before training and 0.79 (95% CI: 0.76–0.80) after training (P = 0.002). Conclusion: Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.
Keywords

MeSH

DOI
10.3348/kjr.2023.0528
PMID
38184765
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Ajou Authors
김, 태희
Full Text Link
Files in This Item:
38184765.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse