Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial

DC Field Value Language
dc.contributor.authorPaik, WH-
dc.contributor.authorJung, MK-
dc.contributor.authorKim, DU-
dc.contributor.authorSong, TJ-
dc.contributor.authorYang, MJ-
dc.contributor.authorChoi, YH-
dc.contributor.authorKim, JS-
dc.contributor.authorLee, MW-
dc.contributor.authorChoi, JH-
dc.contributor.authorLee, SH-
dc.date.accessioned2024-06-19T07:06:56Z-
dc.date.available2024-06-19T07:06:56Z-
dc.date.issued2024-
dc.identifier.issn0915-5635-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/32512-
dc.description.abstractObjectives: We aimed to evaluate the efficacy and safety of metal stents compared with plastic stents when bilateral side-by-side stents were deployed for malignant hilar biliary obstruction (MHBO). Methods: Fifty patients with unresectable advanced MHBO were randomly assigned to the metal stent (MS, n = 25) or plastic stent group (PS, n = 25). Fully covered self-expandable metal stents with 6 mm diameter and plastic stents with either 7F straight or double pigtail were used for MS and PS groups, respectively. Time to recurrent biliary obstruction (TRBO) was evaluated as the primary outcome. Results: Both groups had 100% technical success rates; 88% and 76% of clinical success rates were obtained in MS and PS, respectively. Although stent migrations were more frequent in MS than PS (48% vs. 16%, P = 0.02), the mean TRBO was significantly longer in MS (190 days; 95% confidence interval [CI] 121–260 days vs. 96 days; 95% CI 50–141 days, P = 0.02). The placement of plastic stents (hazard ratio 2.42; 95% CI 1.24–4.73; P = 0.01) was the only significant risk factor associated with TRBO in multivariable analysis. The rates of adverse events were similar between the two groups (difference 0%; 95% CI −25% to 25%; P > 0.99). Conclusions: During bilateral side-by-side deployment in MHBO, the use of metal stents appears to be preferable to plastic stents in terms of TRBO, despite a higher frequency of stent migration.-
dc.language.isoen-
dc.subject.MESHBile Duct Neoplasms-
dc.subject.MESHCholestasis-
dc.subject.MESHHumans-
dc.subject.MESHProspective Studies-
dc.subject.MESHProsthesis Implantation-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHSelf Expandable Metallic Stents-
dc.subject.MESHStents-
dc.subject.MESHTreatment Outcome-
dc.titleSide-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial-
dc.typeArticle-
dc.identifier.pmid37612129-
dc.subject.keywordcholestasis-
dc.subject.keywordendoscopic retrograde cholangiopancreatography-
dc.subject.keywordKlatskin-
dc.subject.keywordpalliation-
dc.contributor.affiliatedAuthorYang, MJ-
dc.type.localJournal Papers-
dc.identifier.doi10.1111/den.14669-
dc.citation.titleDigestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society-
dc.citation.volume36-
dc.citation.number4-
dc.citation.date2024-
dc.citation.startPage473-
dc.citation.endPage480-
dc.identifier.bibliographicCitationDigestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society, 36(4). : 473-480, 2024-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.eissn1443-1661-
dc.relation.journalidJ009155635-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Gastroenterology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse