Cited 0 times in Scipus Cited Count

Linear Ablation Using a Contact Force-Sensing Catheter in Ablation for Persistent Atrial Fibrillation: A Prospective Randomized Trial

Authors
Lee, DI | Lee, KN  | Roh, SY | Kim, YG | Shim, J | Choi, JI | Kim, YH
Citation
Journal of clinical medicine, 13(23). : 7310-7310, 2024
Journal Title
Journal of clinical medicine
ISSN
2077-0383
Abstract
Background/Objectives: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation with contact force (CF)-sensing technology has improved long-term outcomes in patients with atrial fibrillation. This prospective randomized study aimed to assess the efficacy and safety of CF-sensing technology for additional left atrial (LA) linear ablation of persistent AF (PerAF). Methods: After PVI, anteromitral (AM) line and roof line ablation were performed using a CF-sensing catheter. Patients were randomly assigned to either the CF-sensing (CFS) group or the CF-blind control (Blind) group. The primary endpoint was atrial arrhythmia recurrence. LA late gadolinium enhancement (LA-LGE) MRI was conducted at baseline and 1-year follow-up for long-term lesion evaluation. Results: A total of 62 patients with drug-refractory PerAF were enrolled (mean age: 58 ± 10 years; 77% male). The success rates of AM and roof line block were 97% and 100% in the CFS group (n = 33) and 93% and 90% in the Blind group (n = 29). The time to achieve block was reduced in the CFS group (AM: 36 ± 22 vs. 48 ± 28 min, p = 0.068; roof: 19 ± 14 vs. 27 ± 15 min, p = 0.031). The maximum CF for safety endpoints was significantly lower in the CFS group (AM: 42 vs. 69 g, p < 0.001; roof: 33 vs. 49 g, p = 0.003). Full linear LA-LGE formation on 1-year MRI did not differ significantly between the groups (AM: 17 vs. 36%; roof; 29 vs. 24%, both p = NS). Kaplan–Meier estimates of AF/AT-free survival after ablation procedures were 63.6% in the CFS group and 58.6% in the Blind group (log-rank p = 0.837). Conclusions: In patients with PerAF, additional LA linear ablation following PVI using CF-sensing technology improved procedural safety and reduced the time needed to achieve conduction block. However, it did not significantly influence clinical outcomes or the formation of permanent full linear lesions.
Keywords

DOI
10.3390/jcm13237310
PMID
39685768
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Cardiology
Ajou Authors
이, 광노
Full Text Link
Files in This Item:
There are no files associated with this item.
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse