Automated Measurement of Effective Radiation Dose by 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

Authors
Eom, Y | Park, YJ  | Lee, S | Lee, SJ  | An, YS  | Park, BN  | Yoon, JK
Citation
Tomography (Ann Arbor, Mich.), 10(12). : 2144-2157, 2024
Journal Title
Tomography (Ann Arbor, Mich.)
ISSN
2379-13812379-139X
Abstract
Background/Objectives: Calculating the radiation dose from CT in 18F-PET/CT examinations poses a significant challenge. The objective of this study is to develop a deep learning-based automated program that standardizes the measurement of radiation doses. Methods: The torso CT was segmented into six distinct regions using TotalSegmentator. An automated program was employed to extract the necessary information and calculate the effective dose (ED) of PET/CT. The accuracy of our automated program was verified by comparing the EDs calculated by the program with those determined by a nuclear medicine physician (n = 30). Additionally, we compared the EDs obtained from an older PET/CT scanner with those from a newer PET/CT scanner (n = 42). Results: The CT ED calculated by the automated program was not significantly different from that calculated by the nuclear medicine physician (3.67 ± 0.61 mSv and 3.62 ± 0.60 mSv, respectively, p = 0.7623). Similarly, the total ED showed no significant difference between the two calculation methods (8.10 ± 1.40 mSv and 8.05 ± 1.39 mSv, respectively, p = 0.8957). A very strong correlation was observed in both the CT ED and total ED between the two measurements (r2 = 0.9981 and 0.9996, respectively). The automated program showed excellent repeatability and reproducibility. When comparing the older and newer PET/CT scanners, the PET ED was significantly lower in the newer scanner than in the older scanner (4.39 ± 0.91 mSv and 6.00 ± 1.17 mSv, respectively, p < 0.0001). Consequently, the total ED was significantly lower in the newer scanner than in the older scanner (8.22 ± 1.53 mSv and 9.65 ± 1.34 mSv, respectively, p < 0.0001). Conclusions: We successfully developed an automated program for calculating the ED of torso 18F-PET/CT. By integrating a deep learning model, the program effectively eliminated inter-operator variability.
Keywords

MeSH

DOI
10.3390/tomography10120151
PMID
39728913
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Nuclear Medicine & Molecular Imaging
Ajou Authors
박, 복남  |  박, 용진  |  안, 영실  |  윤, 준기  |  이, 수진
Full Text Link
Files in This Item:
39728913.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse