Complications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, SY | - |
dc.contributor.author | Jang, JW | - |
dc.contributor.author | Lew, H | - |
dc.contributor.author | Kim, SJ | - |
dc.contributor.author | Kim, HY | - |
dc.date.accessioned | 2011-07-22T01:33:38Z | - |
dc.date.available | 2011-07-22T01:33:38Z | - |
dc.date.issued | 2002 | - |
dc.identifier.issn | 0021-5155 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/3517 | - |
dc.description.abstract | PURPOSE: In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket.
METHODS: Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed using the chi-square test. RESULTS: Extrusion rates were significantly lower in the sleeved peg system (10.8%) compared to the nonsleeved peg system (27.2%) (P =.005). The other complications related to motility peg placement were granulation tissue overgrowth (4.2%), hydroxyapatite exposure around peg head (3.0%), and decentered peg (1.9%). CONCLUSIONS: To minimize peg extrusion, the sleeved peg was better than the nonsleeved peg for use in primary motility peg placement. | - |
dc.language.iso | en | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Durapatite | - |
dc.subject.MESH | Eye Enucleation | - |
dc.subject.MESH | Eye Evisceration | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Foreign-Body Migration | - |
dc.subject.MESH | Granuloma, Foreign-Body | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Orbital Implants | - |
dc.subject.MESH | Prosthesis Implantation | - |
dc.subject.MESH | Retrospective Studies | - |
dc.title | Complications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket. | - |
dc.type | Article | - |
dc.identifier.pmid | 11853724 | - |
dc.identifier.url | http://linkinghub.elsevier.com/retrieve/pii/S0021515501004592 | - |
dc.contributor.affiliatedAuthor | 장, 재우 | - |
dc.type.local | Journal Papers | - |
dc.citation.title | Japanese journal of ophthalmology | - |
dc.citation.volume | 46 | - |
dc.citation.number | 1 | - |
dc.citation.date | 2002 | - |
dc.citation.startPage | 103 | - |
dc.citation.endPage | 107 | - |
dc.identifier.bibliographicCitation | Japanese journal of ophthalmology, 46(1). : 103-107, 2002 | - |