Annual Report on External Quality Assessment in Blood Bank Tests in Korea (2004)

DC Field Value Language
dc.contributor.author권, 석운-
dc.contributor.author김, 대원-
dc.contributor.author한, 규섭-
dc.contributor.author김, 현옥-
dc.contributor.author서, 장수-
dc.contributor.author차, 영주-
dc.contributor.author전, 동석-
dc.contributor.author양, 동욱-
dc.contributor.author박, 현준-
dc.contributor.author임, 영애-
dc.contributor.author권, 계철-
dc.contributor.author이, 선호-
dc.date.accessioned2012-02-13T04:52:39Z-
dc.date.available2012-02-13T04:52:39Z-
dc.date.issued2005-
dc.identifier.issn1225-097X-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/5615-
dc.description.abstractWe report here the results of surveys for external quality assessment of blood bank tests performed in 2004. Response rates for the Ist, 2nd and 3rd trial were 96.4%, 96.8%, and 96.8%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 100% and 100%, respectively. In crossmatching test, the accuracy rates were 96.2-97.8% for the compatible samples, 75.5-90.6% for the incompatible samples, and 75.5-90.6% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.8-100% for negative samples and 87.3-98.8% for positive samples. The correct results were reported by 98.8-100% of the surveyed institutions for antibody screening test and 100% for identification test. Forty six institutions gave repeatedly incorrect answers for crossmatching. Nine institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.-
dc.formattext/plain-
dc.language.isoko-
dc.titleAnnual Report on External Quality Assessment in Blood Bank Tests in Korea (2004)-
dc.title.alternative혈액은행검사 신빙도조사 결과보고(2004)-
dc.typeArticle-
dc.identifier.urlhttps://www.jlmqa.org/journal/view.html?volume=27&number=1&spage=85&vmd=Full-
dc.subject.keywordQuality assessment-
dc.subject.keywordBlood bank-
dc.subject.keywordABO grouping-
dc.subject.keywordCrossmatch-
dc.contributor.affiliatedAuthor임, 영애-
dc.type.localJournal Papers-
dc.citation.titleJournal of laboratory medicine and quality assurance-
dc.citation.volume27-
dc.citation.number1-
dc.citation.date2005-
dc.citation.startPage85-
dc.citation.endPage90-
dc.identifier.bibliographicCitationJournal of laboratory medicine and quality assurance, 27(1). : 85-90, 2005-
dc.identifier.eissn2288-7261-
dc.relation.journalidJ11225097X-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Laboratory Medicine
Files in This Item:
Journal of laboratory medicine and quality assurance_27(1)_85-90.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse