Cited 0 times in Scipus Cited Count

Novel approach of predicting fracture load in the human proximal femur using non-invasive QCT imaging technique.

DC Field Value Language
dc.contributor.authorLee, T-
dc.contributor.authorPereira, BP-
dc.contributor.authorChung, YS-
dc.contributor.authorOh, HJ-
dc.contributor.authorChoi, JB-
dc.contributor.authorLim, D-
dc.contributor.authorShin, JH-
dc.date.accessioned2010-12-17T01:57:34Z-
dc.date.available2010-12-17T01:57:34Z-
dc.date.issued2009-
dc.identifier.issn0090-6964-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/641-
dc.description.abstractThis paper presents an analysis of predicting the load-bearing capacities of human femurs using quantitative computer tomography (QCT)-based beam theory. Cross-sectional images of 12 human cadaver femurs (intact bones, age: 39-77 years; male = 8, female = 4) were scanned in conjunction with a calcium hydroxyapatite phantom which has five chambers of known densities. The apparent densities obtained from the scans were used to evaluate the Young's modulus (E) by applying the established empirical relationships. The fracture load of a configuration that simulated single-legged stance was measured experimentally and compared with the predicted failure load using a composite beam theory, plane stress model of the femur. In this model, the failure was assumed to occur at the weakest cross-section through the bone determined from QCT-based structural analysis. In contrast to the other experimental investigations, the setup used in this study considers the entire length of a human femur and also incorporates a novel mechanical jig to mimic the realistic physiological scenario. In one of our earlier studies, simulated lytic defects of varying size were created at the inter-trochanteric region of femurs and their load-bearing capacities were calculated based on their structural properties. Both the results obtained from the current study as well as the ones from our previous study were used to assess the viability of the methodology. A high degree of correlation was observed when the predicted failure loads obtained from the intact femurs and previously studied defective femurs were compared with the ex vivo fracture loads. The coefficients of determination (R(2)) of QCT-derived predicted loads with respect to the measured failure loads were 0.80 for the intact femurs and 0.87 for the defective femurs. The results suggest that the QCT-derived beam analysis provides a viable approach for the assessment of load-bearing capacity in various clinical scenarios.-
dc.formatapplication/pdf-
dc.language.isoen-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAging-
dc.subject.MESHCadaver-
dc.subject.MESHElasticity-
dc.subject.MESHFemale-
dc.subject.MESHFemoral Neck Fractures-
dc.subject.MESHFemur-
dc.subject.MESHHumans-
dc.subject.MESHLinear Models-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHModels, Biological-
dc.subject.MESHRadiographic Image Enhancement-
dc.subject.MESHStress, Mechanical-
dc.subject.MESHTensile Strength-
dc.subject.MESHTomography, X-Ray Computed-
dc.subject.MESHWeight-Bearing-
dc.titleNovel approach of predicting fracture load in the human proximal femur using non-invasive QCT imaging technique.-
dc.typeArticle-
dc.identifier.pmid19288197-
dc.contributor.affiliatedAuthor정, 윤석-
dc.type.localJournal Papers-
dc.identifier.doi10.1007/s10439-009-9670-9-
dc.citation.titleAnnals of biomedical engineering-
dc.citation.volume37-
dc.citation.number5-
dc.citation.date2009-
dc.citation.startPage966-
dc.citation.endPage975-
dc.identifier.bibliographicCitationAnnals of biomedical engineering, 37(5). : 966-975, 2009-
dc.identifier.eissn1573-9686-
dc.relation.journalidJ000906964-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Endocrinology & Metabolism
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse