Cited 0 times in Scipus Cited Count

Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length.

DC Field Value Language
dc.contributor.authorChoi, B-
dc.contributor.authorLee, DO-
dc.contributor.authorMo, SS-
dc.contributor.authorKim, SH-
dc.contributor.authorPark, KH-
dc.contributor.authorChung, KR-
dc.contributor.authorNelson, G-
dc.contributor.authorHan, SH-
dc.date.accessioned2012-04-26T02:00:40Z-
dc.date.available2012-04-26T02:00:40Z-
dc.date.issued2011-
dc.identifier.issn1225-5610-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/6585-
dc.description.abstractOBJECTIVE: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). METHODS: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. RESULTS: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. CONCLUSIONS: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.-
dc.formattext/plain-
dc.language.isoen-
dc.titleThree-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length.-
dc.typeArticle-
dc.subject.keywordOsseointegration-
dc.subject.keywordMini-implant-
dc.subject.keywordFinite element analysis-
dc.subject.keywordVon-Mises stress-
dc.contributor.affiliatedAuthor정, 규림-
dc.type.localJournal Papers-
dc.identifier.doi10.4041/kjod.2011.41.6.423-
dc.citation.titleKorean journal of orthodontics-
dc.citation.volume41-
dc.citation.number6-
dc.citation.date2011-
dc.citation.startPage423-
dc.citation.endPage430-
dc.identifier.bibliographicCitationKorean journal of orthodontics, 41(6). : 423-430, 2011-
dc.identifier.eissn2005-372X-
dc.relation.journalidJ012255610-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Dentistry
Files in This Item:
10.4041_kjod.2011.41.6.423.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse