Cited 0 times in Scipus Cited Count

Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

DC Field Value Language
dc.contributor.authorMeyer, M-
dc.contributor.authorNance, JW Jr-
dc.contributor.authorSchoepf, UJ-
dc.contributor.authorMoscariello, A-
dc.contributor.authorWeininger, M-
dc.contributor.authorRowe, GW-
dc.contributor.authorRuzsics, B-
dc.contributor.authorKang, DK-
dc.contributor.authorChiaramida, SA-
dc.contributor.authorSchoenberg, SO-
dc.contributor.authorFink, C-
dc.contributor.authorHenzler, T-
dc.date.accessioned2013-05-02T02:01:17Z-
dc.date.available2013-05-02T02:01:17Z-
dc.date.issued2012-
dc.identifier.issn0720-048X-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/8145-
dc.description.abstractPURPOSE: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD).



MATERIALS AND METHODS: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61±10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system.



RESULTS: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p=0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy.



CONCLUSION: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.
-
dc.language.isoen-
dc.titleCost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease-
dc.typeArticle-
dc.identifier.pmid21277132-
dc.identifier.urlhttp://linkinghub.elsevier.com/retrieve/pii/S0720-048X(10)00680-7-
dc.contributor.affiliatedAuthor강, 두경-
dc.type.localJournal Papers-
dc.identifier.doi10.1016/j.ejrad.2010.12.055-
dc.citation.titleEuropean journal of radiology-
dc.citation.volume81-
dc.citation.number12-
dc.citation.date2012-
dc.citation.startPage3719-
dc.citation.endPage3725-
dc.identifier.bibliographicCitationEuropean journal of radiology, 81(12). : 3719-3725, 2012-
dc.identifier.eissn1872-7727-
dc.relation.journalidJ00720048X-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Radiology
Files in This Item:
There are no files associated with this item.

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse