dc.description.abstractObjective: There are limited data comparing the alternative cardiopulmomonary resuscitation (CPR) methods (over the head CPR, straddle CPR and one hand CPR) to standard CPR performed by emergency medical technicians (EMTs). Therefore we investigated the efficacy of the alternative CPRs compared to that of standard CPR performed by EMTs in simulated cardiac arrest scenarios. Methods:Thirty EMTs of intermediate level participated in this study. The performance of CPR was defined as the average depth, the total number of chest compressions, and the rate of compressions. EMTs performed three minutes of standard CPR and of alternative CPR on standard simulation mannequins with recording devices. Recorded performance was measured and compared between subgroups by the type of CPR, gender of EMTs and gender with various methods of CPR using ANOVA and t test statistics. Results:The average depth of compressions was 42.3 +/- 5.8, 42.6 +/- 4.7, 43.5 +/- 3.7, 33.8 +/- 6.6 mm (mean +/- standard deviation) respectively in standard CPR, over the head CPR, straddle CPR and one hand CPR. The total number of chest compression was 330.4 +/- 38.1, 334.8 +/- 70.2, 334.0 +/- 34.9, 312.1 +/- 53.5 in 3 minutes. The rate of compressions was found to be 111.5 +/- 10.3, 113.8 +/- 11.6, 110.5 +/- 11.2, 110.7 +/- 11.8 times per minute. The comparison of the performance qualities for the four types of CPR showed that the compression depth was significantly lower in one-hand CPR (p<0.000). No EMT gender difference in the quality of performance of total CPR was noted. Conclusions:The efficacy of alternative CPRs are shown to be similar to that of standard CPR in a compression-only simulation cardiac arrest model.-
dc.language.isoen-
dc.titleThe efficacy of alternative cardiopulmomonary resuscitation methods when compared to standard cardiopulmonary resuscitation: a simulation study-
dc.typeArticle-
dc.subject.keywordAmbulance-
dc.subject.keywordCardiac compression-
dc.subject.keywordConfined space-
dc.subject.keywordEmergency medical technician-
dc.contributor.affiliatedAuthor김, 기운-
dc.type.localJournal Papers-
dc.citation.titleHong Kong journal of emergency medicine-
dc.citation.volume19-
dc.citation.number4-
dc.citation.date2012-
dc.citation.startPage242-
dc.citation.endPage248-
dc.identifier.bibliographicCitationHong Kong journal of emergency medicine, 19(4). : 242-248, 2012-
dc.identifier.eissn2309-5407-
dc.relation.journalidJ010249079-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Emergency Medicine
Files in This Item:
Hong Kong journal of emergency medicine_19(4)_242-248.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse