Cited 0 times in Scipus Cited Count

Initial Experience Using Gasless Transaxillary Robotic Thyroidectomy by a Single Surgeon

DC Field Value Language
dc.contributor.author노, 재형-
dc.contributor.author이, 정훈-
dc.contributor.author나, 국영-
dc.contributor.author이, 잔디-
dc.contributor.author정, 웅윤-
dc.contributor.author소, 의영-
dc.date.accessioned2014-02-11-
dc.date.available2014-02-11-
dc.date.issued2010-
dc.identifier.issn1598-1703-
dc.identifier.urihttp://repository.ajou.ac.kr/handle/201003/9272-
dc.description.abstractPurpose: Various endoscopic thyroidectomy procedures have been designed to minimize visible cervical scarring. However, endoscopic thyroidectomy is a technically challenging procedure that is performed by a limited surgeon. Robotic systems aida surgeon in performing minimally invasive head and neck surgery by offering superior visualization and dexterity. This study reports the initial experience of one surgeon with robotic thyroidectomy to assess the technical feasibility and safety of the approach.



Methods: One hundred four thyroid cancer patients (97 females, 7 males; mean age of 39.8±8.1 years) underwent robotic thyroidectomy using gasless transaxillary approach between November 2008 and October 2009 in Ajou University Hospital. All the procedures were completed successfully using the da Vinci surgical system without open conversion. Patient characteristics, postoperative clinical results, complications, and pathologic details were assessed.



Results: Total thyroidectomy was performed in 25 (24.0%) patients, subtotal thyroidectomy in 13 (12.5%) patients, and unilateral lobectomy in 66 (63.5%) patients. All patients underwent ipsilateral central compartment neck dissection, and two patients underwent selective lymph node (LN) dissection. The mean operation time was 134.5±47.2 min (range 61∼310 min), in which the actual time for the thyroidectomy with lymphadenectomy (console time) was 56.4 min. (range 31∼270). The mean number of LN resected was 3.9 (range 0∼28). There were no serious complications. The mean hospital stay was 2.9±0.9 days (range 2∼7).



Conclusion: Robotic thyroidectomy is a feasible, safe, and cosmetically excellent procedure. The application of robotic technology for thyroid surgeries could be an alternative to endoscopic or conventional open thyroidectomy.
-
dc.language.isoko-
dc.titleInitial Experience Using Gasless Transaxillary Robotic Thyroidectomy by a Single Surgeon-
dc.title.alternative무기하 액와 접근법을 이용한 로봇 갑상선 절제술: 단일 술자에 의한 최초 1년간의 경험-
dc.typeArticle-
dc.identifier.urlhttp://www.kates.or.kr/journal/view.html?book=&start=0&scale=10&key=&key_word=&key1=&key2=&key3=&key4=&key_word1=&key_word2=&key_word3=&key_word4=&adverb1=&adverb2=&adverb3=&adverb4=&Vol=010&Num=03&year1=&year2=&sort=Publisher_date&aut_box=Y&sub_box=Y&sos_box=Y&key_box=Y&pub_box=Y&abs_box=&mod=vol&uid=&multi%5B%5D=325-
dc.subject.keyword로봇갑상선수술-
dc.subject.keyword무기하 액와 접근법-
dc.subject.keyword초기 경험-
dc.subject.keyword수술결과-
dc.subject.keywordRobotic thyroidectomy-
dc.subject.keywordGasless transaxillary approach-
dc.subject.keywordInitial experience-
dc.subject.keywordPostoperative outcome-
dc.contributor.affiliatedAuthor이, 정훈-
dc.contributor.affiliatedAuthor나, 국영-
dc.contributor.affiliatedAuthor이, 잔디-
dc.contributor.affiliatedAuthor소, 의영-
dc.type.localJournal Papers-
dc.citation.titleKorean Journal of Endocrine Surgery-
dc.citation.volume10-
dc.citation.number3-
dc.citation.date2010-
dc.citation.startPage157-
dc.citation.endPage162-
dc.identifier.bibliographicCitationKorean Journal of Endocrine Surgery, 10(3). : 157-162, 2010-
dc.identifier.eissn2287-6782-
dc.relation.journalidJ015981703-
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Surgery
Files in This Item:
Korean Journal of Endocrine Surgery_10(3)_157-162.pdfDownload

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse