Cited 0 times in
Optical immunosensor for quantifying C-telopeptide fragments of type II collagen as an osteoarthritis biomarker in urine.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, SJ | - |
dc.contributor.author | Park, YM | - |
dc.contributor.author | Min, BH | - |
dc.contributor.author | Lee, DS | - |
dc.contributor.author | Yoon, HC | - |
dc.date.accessioned | 2014-05-28T04:02:20Z | - |
dc.date.available | 2014-05-28T04:02:20Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1976-0280 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/10212 | - |
dc.description.abstract | A fluorescence-based biosensor for measuring the quantity of C-telopeptide fragments of type II collagen (CTX-II) was developed as an osteoarthritis biomarker in urine. During osteoarthritis progression, joint components such as cartilage collagen are degraded by collagenase-protease and secreted into the serum as CTX-II. To detect CTX-II in urine (uCTX-II) having structural heterogeneity, conventional sandwich format assay does not provide sufficient accuracy. As an alternative, a competitive immunoassay was developed for the quantification of uCTX-II, which uses antibody-conjugated fluoro-microbeads to generate an optical signal. After preparing the biosensing surface, the uCTX-II sample and antibody-optical probe conjugates were reacted on the PEG4-EKGPDP exposed biosensing surface. The optical probes competed with the uCTX-II in the sample for binding to the immobilized PEG4-EKGPDP. This assay was able to detect uCTX-II concentrations between 200 ng/mmol (corrected value vs. creatinine) and 1,400 ng/mmol, encompassing the clinical detection ranges required for osteoarthritis diagnosis. The competitive immunoassay developed for uCTX-II detection was rapid and exhibited good correlation with conventional ELISA methods. This novel competition assay is a promising tool for the diagnosis and monitoring of osteoarthritis using urine samples. | - |
dc.language.iso | en | - |
dc.title | Optical immunosensor for quantifying C-telopeptide fragments of type II collagen as an osteoarthritis biomarker in urine. | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 민, 병현 | - |
dc.type.local | Journal Papers | - |
dc.citation.title | Biochip journal | - |
dc.citation.volume | 7 | - |
dc.citation.number | 4 | - |
dc.citation.date | 2013 | - |
dc.citation.startPage | 399 | - |
dc.citation.endPage | 407 | - |
dc.identifier.bibliographicCitation | Biochip journal, 7(4). : 399-407, 2013 | - |
dc.identifier.eissn | 2092-7843 | - |
dc.relation.journalid | J019760280 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.