Cited 0 times in
Preliminary research to determine the distribution characteristics of indoor air radon concentration in a hot spring bath.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, H | - |
dc.contributor.author | Lee, C | - |
dc.contributor.author | Lee D | - |
dc.contributor.author | Kang, D | - |
dc.contributor.author | Park, J | - |
dc.contributor.author | Kim, S | - |
dc.date.accessioned | 2018-06-28T04:05:30Z | - |
dc.date.available | 2018-06-28T04:05:30Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 2288-9167 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/15374 | - |
dc.description.abstract | This study was performed as the preliminary research to calculate the concentration of radon exposure and the annual effective dose in public hot spring bath-house. The research found that public bathhouses are the primary cause of the indoor air radon concentration inside a hot spring bathhouse. The indoor radon concentration inside a bathhouse differs significantly by region and among bathhouses in the same region, indicating that the indoor air radon concentration is affected by many factors. The annual effective indoor radon dose by exposure is estimated to range from 1.2×10−2mSv/y to 2.5×10−2mSv/y. Since this research is considered as preliminary research, further and additional relevant research to more reliably calculate the result are necessary, including accumulative research for indoor radon concentrations, and research for exposure coefficients such as the behavior patterns of public bathhouse users, etc. | - |
dc.language.iso | ko | - |
dc.title | Preliminary research to determine the distribution characteristics of indoor air radon concentration in a hot spring bath. | - |
dc.title.alternative | 온천탕 실내공기 중 라돈농도 분포 특성 파악을 위한 예비조사 연구 | - |
dc.type | Article | - |
dc.subject.keyword | Effective dose evaluation | - |
dc.subject.keyword | Hot spring bath | - |
dc.subject.keyword | Indoor radon | - |
dc.subject.keyword | Radon concentration | - |
dc.contributor.affiliatedAuthor | 강, 대용 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.15250/joie.2016.15.1.60 | - |
dc.citation.title | Journal of Odor and Indoor Environment | - |
dc.citation.volume | 15 | - |
dc.citation.number | 1 | - |
dc.citation.date | 2016 | - |
dc.citation.startPage | 60 | - |
dc.citation.endPage | 67 | - |
dc.identifier.bibliographicCitation | Journal of Odor and Indoor Environment, 15(1). : 60-67, 2016 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.identifier.eissn | 2288-923X | - |
dc.relation.journalid | J022889167 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.