dc.description.abstract | This study was conducted to provide fundamental data on the distribution of radon concentrations in child day-care facilities in South Korea and to help establish radon mitigation strategies. For this study, 230 child-care centers were randomly chosen from all child-care centers nationwide, and alpha track detectors were used to examine cumulative radon exposure concentrations from January to May 2015. The mean radon concentration measured in Korean child-care centers is approximately 52 Bq m(-3), about one-third of the upper limit of 148 Bq m(-3), which is recommended by South Korea's Indoor Air Quality Control in Public Use Facilities, etc. Act and the U.S. Environmental Protection Agency (EPA). Furthermore, this concentration is about 50% lower than 102 Bq m(-3), which is the measured concentration of radon in houses nationwide from December 2013 to February 2014. Our results indicate that the amount of ventilation, as a major determining factor for indoor radon concentrations, is strongly correlated with the fluctuation of indoor radon concentrations in Korean child-care centers. | - |
dc.format | application/pdf | - |
dc.language.iso | en | - |
dc.subject.MESH | Air Pollutants, Radioactive | - |
dc.subject.MESH | Air Pollution, Indoor | - |
dc.subject.MESH | Child Day Care Centers | - |
dc.subject.MESH | Child, Preschool | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Radiation Monitoring | - |
dc.subject.MESH | Radon | - |
dc.subject.MESH | Republic of Korea | - |
dc.subject.MESH | Ventilation | - |
dc.title | Distribution of radon concentrations in child-care facilities in South Korea | - |
dc.type | Article | - |
dc.identifier.pmid | 27998627 | - |
dc.contributor.affiliatedAuthor | 강, 대용 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.1016/j.jenvrad.2016.11.021 | - |
dc.citation.title | Journal of environmental radioactivity | - |
dc.citation.volume | 167 | - |
dc.citation.date | 2017 | - |
dc.citation.startPage | 80 | - |
dc.citation.endPage | 85 | - |
dc.identifier.bibliographicCitation | Journal of environmental radioactivity, 167. : 80-85, 2017 | - |