Cited 0 times in
Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, HK | - |
dc.date.accessioned | 2019-11-13T00:18:14Z | - |
dc.date.available | 2019-11-13T00:18:14Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 2005-7806 | - |
dc.identifier.uri | http://repository.ajou.ac.kr/handle/201003/16924 | - |
dc.description.abstract | PURPOSE: The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers.
MATERIALS AND METHODS: The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (alpha=.05). RESULTS: A high level of measurement repeatability (ICC>0.90) among L(*), a(*), and b(*) color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were 2.28+/-1.61 DeltaE00 for in-vivo readings. Regarding the clinical matching accuracy of both devices, DeltaE00 values between teeth and matching shade tabs were 3.05+/-1.19 and 2.86+/-1.02, respectively. CONCLUSION: Although two EasyShade V devices with different serial numbers show high repeatability of CIE L(*), a(*), and b(*) measurements, they could provide different color values and shade for the same tooth. | - |
dc.language.iso | en | - |
dc.title | Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study | - |
dc.type | Article | - |
dc.identifier.pmid | 29930796 | - |
dc.identifier.url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004350/ | - |
dc.subject.keyword | Color | - |
dc.subject.keyword | Dimensional measurement accuracy | - |
dc.subject.keyword | Equipment failure analysis | - |
dc.subject.keyword | Spectrophotometry | - |
dc.contributor.affiliatedAuthor | 김, 희경 | - |
dc.type.local | Journal Papers | - |
dc.identifier.doi | 10.4047/jap.2018.10.3.252 | - |
dc.citation.title | The journal of advanced prosthodontics | - |
dc.citation.volume | 10 | - |
dc.citation.number | 3 | - |
dc.citation.date | 2018 | - |
dc.citation.startPage | 252 | - |
dc.citation.endPage | 258 | - |
dc.identifier.bibliographicCitation | The journal of advanced prosthodontics, 10(3). : 252-258, 2018 | - |
dc.identifier.eissn | 2005-7814 | - |
dc.relation.journalid | J020057806 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.