Cited 0 times in Scipus Cited Count

Accuracy of one-step automated orthodontic diagnosis model using a convolutional neural network and lateral cephalogram images with different qualities obtained from nationwide multi-hospitals

Authors
Yim, S | Kim, S | Kim, I | Park, JW | Cho, JH | Hong, M | Kang, KH | Kim, M | Kim, SJ | Kim, YJ | Kim, YH  | Lim, SH | Sung, SJ | Kim, N | Baek, SH
Citation
Korean journal of orthodontics, 52(1). : 3-19, 2022
Journal Title
Korean journal of orthodontics
ISSN
2234-75182005-372X
Abstract
OBJECTIVE: The purpose of this study was to investigate the accuracy of one-step automated orthodontic diagnosis of skeletodental discrepancies using a convolutional neural network (CNN) and lateral cephalogram images with different qualities from nationwide multi-hospitals. METHODS: Among 2,174 lateral cephalograms, 1,993 cephalograms from two hospitals were used for training and internal test sets and 181 cephalograms from eight other hospitals were used for an external test set. They were divided into three classification groups according to anteroposterior skeletal discrepancies (Class I, II, and III), vertical skeletal discrepancies (normodivergent, hypodivergent, and hyperdivergent patterns), and vertical dental discrepancies (normal overbite, deep bite, and open bite) as a gold standard. Pre-trained DenseNet-169 was used as a CNN classifier model. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis, t-stochastic neighbor embedding (t-SNE), and gradientweighted class activation mapping (Grad-CAM). RESULTS: In the ROC analysis, the mean area under the curve and the mean accuracy of all classifications were high with both internal and external test sets (all, > 0.89 and > 0.80). In the t-SNE analysis, our model succeeded in creating good separation between three classification groups. Grad-CAM figures showed differences in the location and size of the focus areas between three classification groups in each diagnosis. CONCLUSIONS: Since the accuracy of our model was validated with both internal and external test sets, it shows the possible usefulness of a one-step automated orthodontic diagnosis tool using a CNN model. However, it still needs technical improvement in terms of classifying vertical dental discrepancies.
Keywords

DOI
10.4041/kjod.2022.52.1.3
PMID
35046138
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Dentistry
Ajou Authors
김, 영호
Full Text Link
Files in This Item:
35046138.pdfDownload
Export

qrcode

해당 아이템을 이메일로 공유하기 원하시면 인증을 거치시기 바랍니다.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.