129 240

Cited 0 times in

Characterization of Noise Exposure in the Tank Gun Drill Ranges

Other Title
군대 전차포 훈련장에서의 소음노출 특성
Authors
황, 성호; 박, 재범
Citation
Journal of Korean Society of Occupational and environmental hygiene, 24(1):74-78, 2014
Journal Title
Journal of Korean Society of Occupational and environmental hygiene; 한국산업위생학회지
ISSN
1226-4326
Abstract
Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges.



Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro™) with the value of Peak(dB(A)).



Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p 0.05).



Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.
Keywords
cannonball sizedistanceimpulse noisenoise exposure
Appears in Collections:
Journal Papers > School of Medicine / Graduate School of Medicine > Occupational & Environmental Medicine